Some 1997-2007 Ford Crown Victoria models may exhibit a no-crank condition due to an open circuit in the starter relay to starter motor circuit at the starter motor connections.

A new starter terminal wiring pigtail is available, eliminating the need to replace the entire harness for the terminal connection.

The new wiring pigtail is available as P/N 6U2Z-14S411-NA. The terminal kit only services the starter relay to starter motor circuit.

The kit does not service the starter motor battery power circuit.